Skip to main content
Protector Guardrail complete set
Permanent collective protection — the standard, not the exception

Why Protector GuardrailProtector Guardrail

Four dimensions on which Protector Guardrail defines the category of industrial safety. Structural engineering combined with regulatory excellence.

Permanent safety, no temporary risks

The market often wrongly compares permanent systems against EN 13374. This is a standard for temporary construction-site edge protection (max. 6 months) that must already be dismantled at wind force 6. A ‘temporary’ solution on a permanent building is technically irresponsible and brings risks and unnecessary costs.

Protector Guardrail is the only structural, permanent solution. Discover the difference:

Temporary system Protector Guardrail
Availability Temporary system:  Only during setup Protector Guardrail:  Always present
Wind load Temporary system:  Limited (storm-sensitive) Protector Guardrail:  Structurally calculated (EN 1991)
Risk profile Temporary system:  Risk at every assembly and dismantle Protector Guardrail:  Safe basis (one-time)
PPE & rescue Temporary system:  Annual inspection and rescue plan required Protector Guardrail:  Not needed
Documentation Temporary system:  Often incomplete Protector Guardrail:  Full lifecycle dossier
TCO (25 years) Temporary system:  High — recurring per deployment Protector Guardrail:  One-time investment
Request a calculation

No obligation · reply within 1 working day

Individual PPE: the last resort, not the solution

Under EU Directive 89/391/EEC, safety managers are legally required to give collective measures priority over individual protection.

  1. 01
    Primary measure

    Collective protection

    Required by law before any individual measure is considered.

  2. 02
    Derogation

    Organisational measures

    Permitted only when collective protection is technically infeasible.

  3. 03
    Last resort

    Individual PPE

    Documented justification required when tiers 01 and 02 cannot apply.

A system that works regardless of what anyone does

No training dependency

Unlike lifeline systems, Protector Guardrail requires no certification, annual training, or specific user knowledge to prevent a fall.

No supervision required

Eliminate the liability of checking whether workers are correctly harnessed. The structure is the supervisor.

No gaps

Human error causes 85% of roof incidents. Protector Guardrail removes the human variable from the safety equation entirely.

Close your compliance gaps

Request the technical documentation and quotation and close your critical compliance gaps.

Three drawn cookies inspecting, like cookie inspectors, a roof with fall protection

Analytics cookies let us measure how this website is used so we can improve it. Data may be shared with an external analytics service for this. We only place these cookies with your consent; if you decline, we place no tracking cookies at all. Privacy statement

Parts of this page were translated with AI.